Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 9.252
Filtrar
1.
Biomed Eng Online ; 23(1): 39, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38566181

RESUMO

BACKGROUND: Congenital heart disease (CHD) is one of the most common birth defects in the world. It is the leading cause of infant mortality, necessitating an early diagnosis for timely intervention. Prenatal screening using ultrasound is the primary method for CHD detection. However, its effectiveness is heavily reliant on the expertise of physicians, leading to subjective interpretations and potential underdiagnosis. Therefore, a method for automatic analysis of fetal cardiac ultrasound images is highly desired to assist an objective and effective CHD diagnosis. METHOD: In this study, we propose a deep learning-based framework for the identification and segmentation of the three vessels-the pulmonary artery, aorta, and superior vena cava-in the ultrasound three vessel view (3VV) of the fetal heart. In the first stage of the framework, the object detection model Yolov5 is employed to identify the three vessels and localize the Region of Interest (ROI) within the original full-sized ultrasound images. Subsequently, a modified Deeplabv3 equipped with our novel AMFF (Attentional Multi-scale Feature Fusion) module is applied in the second stage to segment the three vessels within the cropped ROI images. RESULTS: We evaluated our method with a dataset consisting of 511 fetal heart 3VV images. Compared to existing models, our framework exhibits superior performance in the segmentation of all the three vessels, demonstrating the Dice coefficients of 85.55%, 89.12%, and 77.54% for PA, Ao and SVC respectively. CONCLUSIONS: Our experimental results show that our proposed framework can automatically and accurately detect and segment the three vessels in fetal heart 3VV images. This method has the potential to assist sonographers in enhancing the precision of vessel assessment during fetal heart examinations.


Assuntos
Aprendizado Profundo , Gravidez , Feminino , Humanos , Veia Cava Superior , Ultrassonografia , Ultrassonografia Pré-Natal/métodos , Coração Fetal/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos
2.
BMC Pregnancy Childbirth ; 24(1): 264, 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38605306

RESUMO

BACKGROUND: Maternal diabetes adversely affects fetal cardiovascular system development. Previous studies have reported that the fetuses of mothers with diabetes exhibit both structural and functional changes; nevertheless, prior studies have not examined the association between glucose control and fetal cardiac morphology and performance. Thus, the objective was to determine the association between fetal cardiac morphology and function and maternal glucose control in type 1 diabetes and to compare the differences in measured cardiac parameters between the fetuses of mothers with diabetes and healthy controls. METHODS: In this prospective, longitudinal case-control study - including 62 pregnant women with type 1 diabetes mellitus and 30 healthy pregnant women - fetal cardiac assessment using B-mode, M-mode, and spectral pulsed-wave Doppler was performed in the second and third trimesters. In women with T1DM, glycated hemoglobin and data obtained from glucose sensors - including the percentage of time in, below, and above the range (TIR, TBR, and TAR, respectively), and coefficient of variation (CV) - were analyzed across three time periods: the last menstrual period to 13 (V1), 14-22 (V2), and 23-32 weeks (V3) of gestation. Fetal cardiac indices were compared between groups, and the correlation between glucose control and fetal cardiac indices was assessed. RESULTS: At 28-32 weeks, the fetuses of women with T1DM exhibited increased left ventricular end-diastolic length, relative interventricular septum thickness, right ventricular cardiac output, and pulmonary valve peak systolic velocity compared with healthy controls. At 18-22 weeks, pulmonary and aortic valve diameters, left and right ventricular stroke volumes, and left cardiac output inversely correlated with the CV and glycated hemoglobin levels at V1 and V2. Furthermore, at 28-32 weeks, pulmonary and aortic valve diameters, left ventricular stroke volume, cardiac output, and right/left atrioventricular valve ratio inversely correlated with the TBR at V1, V2, and V3. Moreover, diastolic functional parameters correlated with the TAR and glycated hemoglobin levels, particularly after the first trimester. CONCLUSION: In women with T1DM, maternal hyperglycemia during pregnancy correlates with fetal diastolic function, whereas glucose variability and hypoglycemia inversely correlate with fetal left ventricular systolic function in the second and third trimesters.


Assuntos
Diabetes Mellitus Tipo 1 , Diabetes Gestacional , Síndrome de Quebra de Nijmegen , Gravidez , Humanos , Feminino , Diabetes Mellitus Tipo 1/complicações , Ecocardiografia Doppler , Glicemia , Hemoglobinas Glicadas , Estudos Prospectivos , Estudos de Casos e Controles , Estudos Longitudinais , Coração Fetal/diagnóstico por imagem , Hemodinâmica , Ultrassonografia Pré-Natal
3.
Radiol Cardiothorac Imaging ; 6(2): e230182, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38602469

RESUMO

Fetal cardiac MRI using Doppler US gating is an emerging technique to support prenatal diagnosis of congenital heart disease and other cardiovascular abnormalities. Analogous to postnatal electrocardiographically gated cardiac MRI, this technique enables directly gated MRI of the fetal heart throughout the cardiac cycle, allowing for immediate data reconstruction and review of image quality. This review outlines the technical principles and challenges of cardiac MRI with Doppler US gating, such as loss of gating signal due to fetal movement. A practical workflow of patient preparation for the use of Doppler US-gated fetal cardiac MRI in clinical routine is provided. Currently applied MRI sequences (ie, cine or four-dimensional flow imaging), with special consideration of technical adaptations to the fetal heart, are summarized. The authors provide a literature review on the clinical benefits of Doppler US-gated fetal cardiac MRI for gaining additional diagnostic information on cardiovascular malformations and fetal hemodynamics. Finally, future perspectives of Doppler US-gated fetal cardiac MRI and further technical developments to reduce acquisition times and eliminate sources of artifacts are discussed. Keywords: MR Fetal, Ultrasound Doppler, Cardiac, Heart, Congenital, Obstetrics, Fetus Supplemental material is available for this article. © RSNA, 2024.


Assuntos
Imageamento por Ressonância Magnética , Cuidado Pré-Natal , Feminino , Gravidez , Humanos , Radiografia , Coração Fetal/diagnóstico por imagem , Tecnologia
5.
J Matern Fetal Neonatal Med ; 37(1): 2323623, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38443062

RESUMO

OBJECTIVE: To describe international surveillance and treatment strategies for managing anti-SSA/Ro autoantibody positive pregnancies. STUDY DESIGN: An electronic REDCap questionnaire was distributed to Fetal Heart Society and North American Fetal Therapy Network members which queried institution-based risk stratification, surveillance methods/frequency, conduction abnormality treatments, and postnatal anti-SSA/Ro pregnancy assessment. RESULTS: 101 responses from 59 centers (59% US, 17% international) were collected. Most (79%) do not risk stratify pregnancies by anti-SSA/Ro titer; those that do use varied cutoff values. Many pregnant rheumatology patients are monitored for cardiac abnormalities regardless of maternal anti-SSA/Ro status. Surveillance strategies were based on maternal factors (anti-SSA/Ro status 85%, titer 25%, prior affected child 79%) and monitoring durations varied. Most respondents treat 2° and 3° fetal atrioventricular block, commonly with dexamethasone and/or IVIG. CONCLUSIONS: Wide variation exists in current fetal cardiac surveillance and treatment for anti-SSA/Ro autoantibody positive pregnancies, highlighting the need for evidence-based protocols to optimize care.


Assuntos
Bloqueio Atrioventricular , Criança , Feminino , Gravidez , Humanos , Autoanticorpos , Coração Fetal , Instalações de Saúde , Cuidado Pré-Natal , Vitaminas
6.
J Am Heart Assoc ; 13(6): e031184, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38497437

RESUMO

BACKGROUND: Distances between delivery and cardiac services can make the care of fetuses with cardiac disease at risk of acute cardiorespiratory instability at birth a challenge. In 2013 we implemented a fetal echocardiography-based algorithm targeting fetuses considered high risk for acute cardiorespiratory instability at ≤2 hours of birth for delivery in our pediatric cardiac operating room of our children's hospital, and, herein, examine our experience. METHODS AND RESULTS: We reviewed maternal and postnatal medical records of all fetuses with cardiac disease encountered January 2013 to March 2022 considered high risk for acute cardiorespiratory instability. Secondary analysis was performed including all fetuses with diagnoses of d-transposition of the great arteries/intact ventricular septum (d-TGA/IVS) and hypoplastic left heart syndrome (HLHS) encountered over the study period. Forty fetuses were considered high risk for acute cardiorespiratory instability: 15 with d-TGA/IVS and 7 with HLHS with restrictive atrial septum, 4 with absent pulmonary valve syndrome, 3 with obstructed anomalous pulmonary veins, 2 with severe Ebstein anomaly, 2 with thoracic/intracardiac tumors, and 7 others. Pediatric cardiac operating room delivery occurred for 33 but not for 7 (5 with d-TGA/IVS, 2 with HLHS with restrictive atrial septum). For high-risk cases, fetal echocardiography had a positive predictive value of 50% for intervention/extracorporeal membrane oxygenation/death at ≤2 hours and 70% at ≤24 hours. Of "low-risk" cases, 6/46 with d-TGA/IVS and 0/45 with HLHS required intervention at ≤2 hours. Fetal echocardiography for predicting intervention/extracorporeal membrane oxygenation/death at ≤2 hours had a sensitivity of 67%, specificity 93%, and positive and negative predictive values of 80% and 87%, respectively, for d-TGA/IVS, and 100%, 95%, 71%, and 100% for HLHS, respectively. CONCLUSIONS: Fetal echocardiography can predict the need for urgent intervention in a majority with d-TGA/IVS and HLHS and in half of the entire spectrum of high-risk cardiac disease.


Assuntos
Cardiopatias Congênitas , Síndrome do Coração Esquerdo Hipoplásico , Transposição dos Grandes Vasos , Gravidez , Recém-Nascido , Feminino , Humanos , Criança , Salas Cirúrgicas , Coração Fetal/diagnóstico por imagem , Coração Fetal/cirurgia , Ultrassonografia Pré-Natal/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Síndrome do Coração Esquerdo Hipoplásico/diagnóstico por imagem , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Estudos Retrospectivos
7.
Pediatr Cardiol ; 45(4): 740-748, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38393337

RESUMO

Morphology and function in a fetal heart with severe tricuspid regurgitation remains challenging. The aim of this study was to assess cardiac morphology and function in fetuses with severe tricuspid regurgitation by fetal heart quantification (HQ) and to assess the practical value of fetal HQ. Clinical information was analyzed for 63 pregnant women who underwent fetal cardiac ultrasonography. The women were divided into those who had a fetus with severe tricuspid regurgitation (n = 20) and those with a normal fetus (n = 40). The global sphericity index (GSI), fractional area change (FAC), and global longitudinal strain (GLS) of both ventricles and the sphericity index (SI) and fractional shortening (FS) of 24 segments were quantified by fetal HQ using speckle tracking imaging. Fetuses with severe tricuspid regurgitation had a significantly lower GSI (1.14 ± 0.10 vs. 1.26 ± 0.08, p < 0.001) and a higher GSI Z-score (-0.98 ± 1.01 vs. 0.25 ± 0.87, p < 0.001) as well as a significantly lower right ventricular FAC (36.50 ± 7.34% vs. 45.19 ± 3.39%, p < 0.001), FAC Z-score (-1.02 ± 1.41 vs. 0.49 ± 0.74, p < 0.001), and GLS (-21.01 ± 5.66% vs. 45.19 ± 3.49%, p < 0.001). The SI and SI Z-score were significantly lower in segments 1-18 of the right ventricle in fetuses with severe tricuspid regurgitation (p < 0.05); furthermore, FS of segments 1-12 and 19-24 and the FS Z-score of segments 18-24 were significantly lower in fetuses with severe tricuspid regurgitation (p < 0.05). Fetal HQ is useful for evaluation of cardiac morphology and function in fetuses with severe tricuspid regurgitation and can provide important reference information for both clinical diagnosis and treatment.


Assuntos
Insuficiência da Valva Tricúspide , Humanos , Feminino , Gravidez , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Coração Fetal/diagnóstico por imagem , Ventrículos do Coração , Ultrassonografia Pré-Natal/métodos
8.
J Perinat Med ; 52(3): 322-326, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38298153

RESUMO

OBJECTIVES: To evaluate the changes of cardiac morphology and function in fetuses conceived through assisted reproductive technologies (ART) by speckle tracking echocardiography. METHODS: A retrospective study was conducted in 101 spontaneously conceived (SC) fetuses and 99 ART-conceived ones. Fetal echocardiography was performed, fetal cardiac morphology and function were analyzed using two-dimensional speckle tracking software, including global sphericity index (GSI), global longitudinal strain (GLS), fractional area change (FAC) of the left and right ventricles, as well as segmental sphericity index (SI), end-diastolic diameter (ED), and fractional shortening (FS) in 24 segments. RESULTS: Compared to the SC fetuses, the ART-conceived fetuses exhibited decreased GSI (median [interquartile range], 1.22 [1.16-1.27] vs. 1.18 [1.11-1.24], p=0.007), decreased right ventricular GLS (24.9 [21.5-27.6] vs. 23.2 [20.4-26.8], p=0.026), and decreased right ventricular FAC (mean ± standard deviation, 39.7 ± 6.4 vs. 37.2 ± 7.1, p=0.003). Analysis of the 24 segments showed that ART-conceived fetuses had reduced SI in the apical segments of right ventricle and increased ED in several segments of the right ventricle. CONCLUSIONS: Fetuses conceived through ART had a more spherical shape of the global heart and predominantly right-sided cardiac remodeling and systolic function impairment.


Assuntos
Ecocardiografia , Coração Fetal , Humanos , Estudos Retrospectivos , Coração Fetal/diagnóstico por imagem , Ecocardiografia/métodos , Ventrículos do Coração/diagnóstico por imagem , Técnicas de Reprodução Assistida
9.
BMC Pregnancy Childbirth ; 24(1): 141, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38365664

RESUMO

OBJECTIVE: Whether or not the effects of anemia in the early phase, while the fetuses attempts to increase cardiac output to meet oxygen requirement in peripheral organs, is detrimental to the fetal developing vital organs is little-known. The objective of this is to compare prenatal cardiovascular changes and post-abortal cellular damages in the myocardium as a pumping organ and the brain as a perfused organ between anemic fetuses (using fetal Hb Bart's disease as a study model) in pre-hydropic phase and non-anemic fetuses. METHODS: Fetuses affected by Hb Bart's disease and non-anemic fetuses at 16-22 weeks were recruited to undergo comprehensive fetal echocardiography. Cord blood analysis was used to confirm the definite diagnosis of fetal Hb Bart's disease and normal fetuses. Fetal cardiac and brain tissues were collected shortly after pregnancy termination for the determination of oxidative stress and mitochondrial function, including mitochondrial ROS production and mitochondrial membrane changes. RESULTS: A total of 18 fetuses affected by Hb Bart's disease and 13 non-anemic fetuses were recruited. The clinical characteristics of both groups were comparable. The affected fetuses showed a significant increase in cardiac dimensions, cardiac function, cardiac output and brain circulation without deteriorating cardiac contractility and preload. However, in the affected fetuses, mitochondrial dysfunction was clearly demonstrated in brain tissues and in the myocardium, as indicated by a significant increase in the membrane potential change (p-value < 0.001), and a significant increase in ROS production in brain tissues, with a trend to increase in myocardium. The findings indicated cellular damage in spite of good clinical compensation. CONCLUSION: The new insight is that, in response to fetal anemia, fetal heart increases in size (dilatation) and function to increase cardiac output and blood flow velocity to provide adequate tissue perfusion, especially brain circulation. However, the myocardium and brain showed a significant increase in mitochondrial dysfunction, suggesting cellular damage secondary to anemic hypoxia. The compensatory increase in circulation could not completely prevent subtle brain and heart damage.


Assuntos
Anemia , Doenças Fetais , Hemoglobinas Anormais , Doenças Mitocondriais , Talassemia alfa , Feminino , Gravidez , Humanos , Segundo Trimestre da Gravidez , Espécies Reativas de Oxigênio , Hemoglobinas Anormais/análise , Doenças Fetais/diagnóstico , Coração Fetal/diagnóstico por imagem , Miocárdio/química , Edema , Débito Cardíaco
10.
J Physiol ; 602(4): 663-681, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38324229

RESUMO

Fetal critical aortic stenosis with evolving hypoplastic left heart syndrome (CAS-eHLHS) causes biomechanical and functional aberrations, leading to a high risk of progression to hypoplastic left heart syndrome (HLHS) at birth. Fetal aortic valvuloplasty (FAV) can resolve outflow obstruction and may reduce progression risk. However, it is currently difficult to accurately predict which patients will respond to the intervention and become functionally biventricular (BV) at birth, as opposed to becoming functionally univentricular (UV). This prediction is important for patient selection, parental counselling, and surgical planning. Therefore, we investigated whether biomechanics parameters from pre-FAV image-based computations could robustly distinguish between CAS-eHLHS cases with BV or UV outcomes in a retrospective cohort. To do so we performed image-based finite element biomechanics modelling of nine CAS-eHLHS cases undergoing intervention and six healthy fetal control hearts, and found that a biomechanical parameter, peak systolic myofibre stress, showed a uniquely large difference between BV and UV cases, which had a larger magnitude effect than echocardiography parameters. A simplified equation was derived for quick and easy estimation of myofibre stress from echo measurements via principal component analysis. When tested on a retrospective cohort of 37 CAS-eHLHS cases, the parameter outperformed other parameters in predicting UV versus BV outcomes, and thus has a high potential of improving outcome predictions, if incorporated into patient selection procedures. Physiologically, high myocardial stresses likely indicate a healthier myocardium that can withstand high stresses and resist pathological remodelling, which can explain why it is a good predictor of BV outcomes. KEY POINTS: Predicting the morphological birth outcomes (univentricular versus biventricular) of fetal aortic valvuloplasty for fetal aortic stenosis with evolving HLHS is important for accurate patient selection, parental counselling and management decisions. Computational simulations show that a biomechanics parameter, pre-intervention peak systolic myofibre stress, is uniquely robust in distinguishing between such outcomes, outperforming all echo parameters. An empirical equation was developed to quickly compute peak systolic myofibre stress from routine echo measurements and was the best predictor of outcomes among a wide range of parameters tested.


Assuntos
Estenose da Valva Aórtica , Síndrome do Coração Esquerdo Hipoplásico , Recém-Nascido , Humanos , Síndrome do Coração Esquerdo Hipoplásico/diagnóstico por imagem , Síndrome do Coração Esquerdo Hipoplásico/terapia , Síndrome do Coração Esquerdo Hipoplásico/etiologia , Estudos Retrospectivos , Estenose da Valva Aórtica/diagnóstico por imagem , Coração Fetal , Miocárdio
11.
J Ultrasound Med ; 43(5): 851-861, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38213069

RESUMO

OBJECTIVES: To investigate whether fetal cardiac function is affected by underlying heart disease in pregnant women. METHODS: A total of 100 pregnant women who were ≥34 gestational weeks were included in the study, 40 in the maternal heart disease (MHD) group diagnosed with heart disease and 60 in the control group. All cardiac diseases in pregnant women were diagnosed preconceptionally and categorized according to the New York Heart Association (NYHA) classification system. Fetal cardiac functions of study groups were evaluated by M-mode, color tissue Doppler imaging (c-TDI), and pulsed wave Doppler. RESULTS: Tricuspid annular plane systolic excursion and myocardial performance index (MPI) values were significantly higher and isovolumetric relaxation time was prolonged in the MHD group. The MPI value was found higher in MHD group with NYHA Class II compared to those with NYHA Class I. No significant change in any of the fetal tricuspid annular peak velocity values measured by c-TDI in the MHD group. There were no differences in fetal cardiac functions and perinatal outcomes between pregnant women with acquired and congenital heart diseases. Patients in NYHA Class II had lower birth weight, 1st and 5th minute APGAR scores, and higher neonatal intensive care unit admission rates. CONCLUSIONS: Underlying heart diseases in pregnant women can cause alterations in the systolic and diastolic function of the fetal heart. High fetal MPI values detected in cardiac patients may indicate that cardiac pathologies during pregnancy affect fetal cardiac globular myocardial function. Cardiac pathologies that progress with restricted physical activity may cause changes in fetal cardiac function and may be associated with adverse perinatal outcomes.


Assuntos
Cardiopatias , Recém-Nascido , Humanos , Gravidez , Feminino , Cardiopatias/complicações , Cardiopatias/diagnóstico por imagem , Coração Fetal/diagnóstico por imagem , Sístole , Estudos Prospectivos , Diástole , Ultrassonografia Pré-Natal/métodos
12.
J Ultrasound Med ; 43(5): 841-849, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38240409

RESUMO

OBJECTIVES: The aims of this study were to assess the vortex characteristics of left ventricle (LV) in fetuses with coarctation of the aorta (CoA) using high-frame rate ultrasound with blood speckle-tracking (BST) and explore its relationships with cardiac function and morphology parameters. METHODS: Thirty fetuses with CoA and 30 gestational-age matched normal fetuses were included in this cross-sectional study. The area, length, width, and position of the vortex in the LV were recorded and quantitatively analyzed by BST echocardiography. The associations of vortex properties with ventricular function and morphology were also determined. RESULTS: Based on BST imaging, the LV vortex can be observed in 93% of the fetuses. The fetuses with CoA exhibited significantly larger and wider vortex than the controls (P < .05). Linear regression analysis indicated that vortex area was positively related to sphericity index of LV as well as isovolumic relaxation time (r = .52, P = .003 and r = .42, P = .021). There was a negative correlation between vortex area and mitral valve size (r = -.443, P = .014). No significant association was found between vortex area and myocardial performance index and aortic isthmus size. CONCLUSIONS: It is feasible to quantitatively evaluate the left ventricular vortex in fetuses by BST. The fetuses with CoA exhibited greater vortex area and width, and the altered vortex property is associated with geometry of LV. This will facilitate our comprehension of the unique flow patterns and early cardiac remodeling in fetuses with CoA.


Assuntos
Coartação Aórtica , Humanos , Gravidez , Feminino , Coartação Aórtica/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Estudos Transversais , Ecocardiografia/métodos , Coração Fetal/diagnóstico por imagem
13.
BMC Pregnancy Childbirth ; 24(1): 57, 2024 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-38212679

RESUMO

BACKGROUND: Hyperglycemia during pregnancy can affect fetal heart in many ways, including causing cardiac malformation, leading to hypertrophic cardiomyopathy and cardiac dysfunction. Echocardiographic evaluation can assist identify alterations in heart structure, morphology and function, enabling prompt monitoring and management. However, according to earlier research, the cardiac alterations are modest in hyperglycemic mothers' fetuses, and might not be detectable using conventional methods and it is also unclear whether these changes are related to the metabolism of mothers. Fetal Heart Quantification (Fetal HQ) can assess ventricular geometry and function more sensitively and thoroughly, and identify sub-clinical cardiac dysfunction. The purpose of this study was to evaluate fetal heart by Fetal HQ in fetuses of hyperglycemic mothers who either had pre-gestational or gestational diabetes and to correlate them with maternal metabolic indices. METHODS: The fetuses of 25 gestational age-matched control mothers, 48 women with gestational diabetes mellitus (GDM), and 11 women with diabetes mellitus (DM) were included in the prospective case-control research. Using fetal echocardiography and speckle tracking echocardiography (STE), the heart of the fetus was evaluated. Differences in the groups' anthropometric, metabolic, and cardiac parameters were examined. It was assessed whether maternal features, prenatal glucose, lipids, and maternal hemoglobin A1c (HbA1c) correlated with fetal cardiac parameters. RESULTS: The LV EDV and ESV were significantly higher in the GDM group as compared to the DM group (p < 0.05). The GSI% was significantly lower in the GDM group compared with the control (p < 0.05). The LV SV and CO of the GDM group were both significantly higher compared with the DM group (p < 0.05). There was a significant decrease in RV FS for segments 1-7 in GDM fetuses compared to the control (p < 0.05) and for segments 5-10 compared to DM (p < 0.05). Fetal cardiac morphology and function indices correlate with maternal pregestational weight, BMI, early pregnancy fast glucose, lipids, and glycemic control levels. CONCLUSIONS: Fetuses exposed to gestational diabetes have altered heart morphology and function that is linked to maternal metabolic parameters, which presents a special indication for performing geometry and function cardiac assessment. Fetal HQ can be employed to evaluate the fetal cardiac shape and function in fetuses exposed to gestational diabetes.


Assuntos
Diabetes Gestacional , Cardiopatias , Gravidez , Feminino , Humanos , Coração Fetal/diagnóstico por imagem , Glucose , Lipídeos , Ultrassonografia Pré-Natal/métodos
14.
Echocardiography ; 41(1): e15743, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38284679

RESUMO

BACKGROUND: Isolated redundant foramen ovale flap aneurysm (RFOA) in the absence of restrictive foramen ovale is believed to be a cause for pseudocoarctation of aorta since the impediment of blood flow to the left heart can be severe, resembling the picture of left ventricular hypoplasia with retrograde aortic flow. The primary objective of the study is to find whether RFOA is always a benign lesion. The main focus of the study is to share my experience in particular on fetuses having redundant foramen ovale flap aneurysm developing into coarctation of aorta and to study the associated factors. METHODS: Retrospective study (January 2020 to June 2023). All fetuses with RFOA associated with and without congenital heart defects were included. Fetuses with restrictive foramen ovale and RFOA with single ventricle hearts were excluded. The imaging, in-utero hemodynamics, pregnancy, and postnatal outcomes with at least 3 months follow-up were presented. RESULTS: During the study period, a total of 1499 fetal echocardiography were performed. Twenty-two fetuses with RFOA were included. Fourteen fetuses had isolated RFOA and eight had associated abnormalities [extracardiac (n = 5); intracardiac (n = 2), Both (n = 1)]. Genetic evaluation were performed only in fetuses with associated defects were normal. Postnatally all isolated RFOA fetuses had no aortic arch obstruction. Fetuses with associated aberrant right subclavian artery, isolated left superior vena cava, absent ductus venosus and ventricular septal defects developed aortic arch obstruction after birth. RFOA causes smallish left ventricle in fetuses with tetralogy of Fallot which recovered to normal size postnatally. CONCLUSION: Isolated RFOA can be benign, however, if it is associated with cardiac or extracardiac anomalies predominantly resulted in aortic arch obstruction. Though it is a cause for pseudocoarctation of aorta, through postnatal reassessment of aortic arch is mandatory. Careful search for intracardiac and systemic venous anomalies is recommended. It created confusion regarding adequacy of left ventricle when associated with congenital heart defects.


Assuntos
Aneurisma , Forame Oval , Cardiopatias Congênitas , Gravidez , Feminino , Humanos , Estudos Retrospectivos , Veia Cava Superior , Ultrassonografia Pré-Natal , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/diagnóstico por imagem , Diagnóstico Pré-Natal , Coração Fetal/diagnóstico por imagem , Hemodinâmica
16.
Echocardiography ; 41(1): e15736, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38284669

RESUMO

OBJECTIVE: To evaluate both short and mid-term effects of maternal COVID-19 on cardiac functions of fetuses and children. METHODS: The present case-control study was conducted on 36 pregnant women who had COVID-19 infection in the second trimester of pregnancy and 30 pregnant women as healthy controls. Fetal, neonatal, and infant cardiac functions were compared between the groups. Assessment of fetal cardiac functions were performed in the last trimester of the pregnancy at least 6 weeks after the recovery of infection. The first postnatal echo was performed within the first 2 weeks and the follow-up (second) echo was performed in the 6-8 weeks of life. RESULTS: The demographic data were similar between groups. Interventricular septum and left ventricular posterior wall end-diastolic dimensions were significantly higher in the study group in both fetal, neonatal, and infant periods. Impaired diastolic functions of right and left ventricles were detected and myocardial performance indexes with tissue doppler imaging of both lateral walls and septum were significantly higher than controls at all periods. CONCLUSION: Maternal COVID-19 seems to have a global impact on the cardiac functions of babies in the short and mid-term periods after maternal recovery.


Assuntos
COVID-19 , Ecocardiografia Doppler , Recém-Nascido , Lactente , Criança , Gravidez , Feminino , Humanos , Ecocardiografia Doppler/métodos , Coração Fetal/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Terceiro Trimestre da Gravidez , Ultrassonografia Pré-Natal/métodos
17.
Reprod Sci ; 31(3): 823-831, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37884730

RESUMO

Fetal sex has been associated with different development trajectories that cause structural and functional differences between the sexes throughout gestation. Fetal magnetocardiography (fMCG) recordings from 123 participants (64 females and 59 males; one recording/participant) from a database consisting of low-risk pregnant women were analyzed to explore and compare fetal development trajectories of both sexes. The gestational age of the recordings ranged from 28 to 38 weeks. Linear metrics in both the time and frequency domains were applied to study fetal heart rate variability (fHRV) measures that reveal the dynamics of short- and long-term variability. Rates of linear change with GA in these metrics were analyzed using general linear model regressions with assessments for significantly different variances and GA regression slopes between the sexes. The fetal sexes were well balanced for GA and sleep state. None of the fHRV measures analyzed exhibited significant variance heterogeneity between the sexes, and none of them exhibited a significant sex-by-GA interaction. The absence of a statistically significant sex-by-GA interaction on all parameters resulted in none of the regression slope estimates being significantly different between the sexes. With high-precision fMCG recordings, we were able to explore the variation in fHRV parameters as it relates to fetal sex. The fMCG-based fHRV parameters did not show any significant difference in rates of change with gestational age between sexes. This study provides a framework for understanding normal development of the fetal autonomic nervous system, especially in the context of fetal sex.


Assuntos
Magnetocardiografia , Masculino , Gravidez , Humanos , Feminino , Lactente , Frequência Cardíaca , Magnetocardiografia/métodos , Frequência Cardíaca Fetal/fisiologia , Desenvolvimento Fetal/fisiologia , Idade Gestacional , Terceiro Trimestre da Gravidez , Coração Fetal
18.
Comput Biol Med ; 168: 107741, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38042103

RESUMO

In prenatal ultrasound screening, rapid and accurate recognition of the fetal heart ultrasound standard planes(FHUSPs) can more objectively predict fetal heart growth. However, the small size and movement of the fetal heart make this process more difficult. Therefore, we design a deep learning-based FHUSP recognition network (FHUSP-NET), which can automatically recognize the five FHUSPs and detect tiny key anatomical structures at the same time. 3360 ultrasound images of five FHUSPs from 1300 mid-pregnancy pregnant women are included in this study. 10 fetal heart key anatomical structures are manually annotated by experts. We apply spatial pyramid pooling with a fully connected spatial pyramid convolution module to capture information about targets and scenes of different sizes as well as improve the perceptual ability and feature representation of the model. Additionally, we adopt the squeeze-and-excitation networks to improve the sensitivity of the model to the channel features. We also introduce a new loss function, the efficient IOU loss, which makes the model effective for optimizing similarity. The results demonstrate the superiority of FHUSP-NET in detecting fetal heart key anatomical structures and recognizing FHUSPs. In the detection task, the value of mAP@0.5, precision, and recall are 0.955, 0.958, and 0.931, respectively, while the accuracy reaches 0.964 in the recognition task. Furthermore, it takes only 13.6 ms to detect and recognize one FHUSP image. This method helps to improve ultrasonographers' quality control of the fetal heart ultrasound standard plane and aids in the identification of fetal heart structures in a less experienced group of physicians.


Assuntos
Coração Fetal , Ultrassonografia Pré-Natal , Feminino , Gravidez , Humanos , Coração Fetal/diagnóstico por imagem , Ultrassonografia Pré-Natal/métodos , Ecocardiografia , Desenvolvimento Fetal
19.
Arthritis Rheumatol ; 76(3): 345-347, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37965716

Assuntos
Coração Fetal
20.
J Perinat Med ; 52(2): 239-245, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-37853744

RESUMO

OBJECTIVES: To demonstrate possible functional changes in the frequently affected fetal interventricular septum (IVS) with spectral tissue Doppler imaging (TDI) and M-mode imaging to compare gestational diabetes mellitus (GDM) and control groups. METHODS: A total of 63 pregnant women with GDM, 30 on diet (A1 GDM) and 33 on treated with insulin (A2 GDM), and 63 healthy pregnant women randomly selected and matched to the case group in the control group were included. RESULTS: The GDM fetuses had significantly thickened IVS, increased early diastole (E'), atrial contraction (A'), systole (S'), higher myocardial performance index (MPI'), prolonged isovolumetric relaxation time (IVRT'), shortened ejection time (ET'), and decreased septal annular plane systolic excursion (SAPSE) than the controls. The A2 GDM group fetuses had significantly thickened IVS, increased S' and shortened ET' than the A1 GDM group. In the GDM group, we found a significantly positive low correlation between glycated hemoglobin levels and maternal serum fasting glucose and one-hour postprandial glucose with fetal IVS thickness. We demonstrated a significantly negative low correlation between maternal serum one-hour postprandial glucose, glycated hemoglobin levels, and gestational weight gain with fetal IVS ET'. CONCLUSIONS: Fetal IVS diastolic and systolic functions were altered in the GDM group compared to controls, and systolic functions were altered in A2 GDM compared to A1 GDM. This may alert clinicians to possible cardiovascular diseases in the postnatal life, and early preventive strategies and long-term lifestyle changes may provide protection in fetuses with GDM.


Assuntos
Diabetes Gestacional , Gravidez , Feminino , Humanos , Diabetes Gestacional/diagnóstico por imagem , Estudos de Casos e Controles , Hemoglobinas Glicadas , Feto , Glucose , Coração Fetal/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...